Warning w0026: "Loading results failed: Incorrect coordinate system."

Follow

Warning

"Loading results failed: Incorrect coordinate system".

 

Description

When opening a project previously processed, the following warning message is displayed:
w0026: "Loading results failed: Incorrect coordinate system."

 

Cause

One possible cause is that the user had an initial coordinate system for the project and then added GCPs with a different coordinate system without Reoptimizing.

 

Solution

The results cannot be loaded. The project needs to be processed again. When adding GCPs to a project, the user should always Reoptimize before running other steps of processing and / or closing the project.

 